{"id":3654,"date":"2026-10-28T14:17:17","date_gmt":"2026-10-28T19:17:17","guid":{"rendered":"https:\/\/comindindustries.com\/producto\/logbox-aa-analog-signal-logger\/"},"modified":"2026-11-10T09:07:28","modified_gmt":"2026-11-10T12:07:28","slug":"logbox-aa-analog-signal-logger","status":"publish","type":"product","link":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/","title":{"rendered":"LogBox-AA Analog Signal Logger"},"content":{"rendered":"<p><strong>The LogBox-AA Data Logger is a versatile, high-precision standalone electronic data recorder<\/strong>, designed to meet the critical demands of monitoring and acquiring analog variables in demanding industrial environments.<\/p>\n<p><strong>Equipped with two universal multi-sensor input channels<\/strong>, this device allows flexible connection of temperature sensors (Pt100 and J, K, T, E, N, R, S, B thermocouples) as well as voltage (0-50 mV, 0-10 V) and current (0-20 mA or 4-20 mA) signals. With an [IP65 \/ IP67] protection rating, it ensures reliable performance both indoors and at remote outdoor measuring points.<\/p>\n<p>It also includes an innovative auxiliary electronic switch that powers external sensors only during measurement, drastically extending system battery life and reducing preventive maintenance costs in the field.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Specifications:\u00a0<\/strong><\/p>\n<ul>\n<li>Input channels: 2 universal multi-sensor analog input channels<\/li>\n<li>Input types: Pt100, thermocouples (J, K, T, E, N, R, S, B), voltage (0 to 50 mV, 0 to 10 V), current (0 to 20 mA, 4 to 20 mA)<\/li>\n<li>Memory capacity: up to 64,000 records (64k model), split or assigned per channel<\/li>\n<li>Accuracy: 0.2% of full range (Pt100, mA, V, mV) \/ 0.25% of full range (thermocouples)<\/li>\n<li>Input resolution: 14 bits<\/li>\n<li>Operating temperature: -40 \u00b0C to 70 \u00b0C (except thermocouples | 0 \u00b0C to 70 \u00b0C)<\/li>\n<li>Enclosure: IP65 in ABS + PC. Optional: IP67<\/li>\n<li>Dimensions: 70 x 60 x 35 mm<\/li>\n<\/ul>\n<p><strong>*Photo for reference only<\/strong><\/p>\n","protected":false},"featured_media":3655,"comment_status":"open","ping_status":"closed","template":"","meta":{"_joinchat":[]},"product_brand":[],"product_cat":[763],"product_tag":[],"class_list":["post-3654","product","type-product","status-publish","has-post-thumbnail","product_cat-monitoring-and-recording","first","instock","shipping-taxable","product-type-variable","has-default-attributes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>LogBox-AA Analog Signal Logger - Comind Industries<\/title>\n<meta name=\"description\" content=\"LogBox-AA analog data logger with 2 universal channels (Pt100, TC, mA, V), long battery life and up to 64k memory. Request a quote from Comind.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"LogBox-AA Analog Signal Logger - Comind Industries\" \/>\n<meta property=\"og:description\" content=\"LogBox-AA analog data logger with 2 universal channels (Pt100, TC, mA, V), long battery life and up to 64k memory. Request a quote from Comind.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/\" \/>\n<meta property=\"og:site_name\" content=\"Comind Industries\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-10T12:07:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/comindindustries.com\/wp-content\/uploads\/2026\/10\/LogBox-AA-Comind.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2048\" \/>\n\t<meta property=\"og:image:height\" content=\"2048\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/\",\"url\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/\",\"name\":\"LogBox-AA Analog Signal Logger - Comind Industries\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/comindindustries.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/LogBox-AA-Comind.webp\",\"datePublished\":\"2026-10-28T19:17:17+00:00\",\"dateModified\":\"2026-11-10T12:07:28+00:00\",\"description\":\"LogBox-AA analog data logger with 2 universal channels (Pt100, TC, mA, V), long battery life and up to 64k memory. Request a quote from Comind.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/#primaryimage\",\"url\":\"https:\\\/\\\/comindindustries.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/LogBox-AA-Comind.webp\",\"contentUrl\":\"https:\\\/\\\/comindindustries.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/LogBox-AA-Comind.webp\",\"width\":2048,\"height\":2048,\"caption\":\"LogBox-AA Analog Signal Logger\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/product\\\/logbox-aa-analog-signal-logger\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"LogBox-AA Analog Signal Logger\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/#website\",\"url\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/\",\"name\":\"Comind Industries\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/comindindustries.com\\\/us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"LogBox-AA Analog Signal Logger - Comind Industries","description":"LogBox-AA analog data logger with 2 universal channels (Pt100, TC, mA, V), long battery life and up to 64k memory. Request a quote from Comind.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"LogBox-AA Analog Signal Logger - Comind Industries","og_description":"LogBox-AA analog data logger with 2 universal channels (Pt100, TC, mA, V), long battery life and up to 64k memory. Request a quote from Comind.","og_url":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/","og_site_name":"Comind Industries","article_modified_time":"2026-11-10T12:07:28+00:00","og_image":[{"width":2048,"height":2048,"url":"https:\/\/comindindustries.com\/wp-content\/uploads\/2026\/10\/LogBox-AA-Comind.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/","url":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/","name":"LogBox-AA Analog Signal Logger - Comind Industries","isPartOf":{"@id":"https:\/\/comindindustries.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/#primaryimage"},"image":{"@id":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/#primaryimage"},"thumbnailUrl":"https:\/\/comindindustries.com\/wp-content\/uploads\/2026\/10\/LogBox-AA-Comind.webp","datePublished":"2026-10-28T19:17:17+00:00","dateModified":"2026-11-10T12:07:28+00:00","description":"LogBox-AA analog data logger with 2 universal channels (Pt100, TC, mA, V), long battery life and up to 64k memory. Request a quote from Comind.","breadcrumb":{"@id":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/#primaryimage","url":"https:\/\/comindindustries.com\/wp-content\/uploads\/2026\/10\/LogBox-AA-Comind.webp","contentUrl":"https:\/\/comindindustries.com\/wp-content\/uploads\/2026\/10\/LogBox-AA-Comind.webp","width":2048,"height":2048,"caption":"LogBox-AA Analog Signal Logger"},{"@type":"BreadcrumbList","@id":"https:\/\/comindindustries.com\/us\/product\/logbox-aa-analog-signal-logger\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/comindindustries.com\/us\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/comindindustries.com\/us\/shop\/"},{"@type":"ListItem","position":3,"name":"LogBox-AA Analog Signal Logger"}]},{"@type":"WebSite","@id":"https:\/\/comindindustries.com\/us\/#website","url":"https:\/\/comindindustries.com\/us\/","name":"Comind Industries","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/comindindustries.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/product\/3654","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/comments?post=3654"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/media\/3655"}],"wp:attachment":[{"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/media?parent=3654"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/product_brand?post=3654"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/product_cat?post=3654"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/comindindustries.com\/us\/wp-json\/wp\/v2\/product_tag?post=3654"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}