N1500-LC Load Cell Indicator

Quote on request

– Easily configurable from the front keypad
– Configurable input for: 0-20 mV, -20 to 20 mV, 0-50 mV, 0-20 mA and 4-20 mA
– 62000-level display resolution with range programmable from -31000 to +31000 via keypad
– Adjustable digital filter
– Accuracy: 0.20 % of full span
– Linear current and voltage: 0.15 % of full span
– Input sampling: 15 measurements per second
– Alarms: 2 alarm relays 3 SPDT 250 Vac in the basic version and 2 optional SPST relays, all with timing and reconnection lockout options
– Alarm functions: high, low, high differential or low differential, and sensor break
– High-brightness 6-digit display, 13 mm high
– Hold function and minimum and maximum peak detection
– Tare and tare zero via front keypad and tare via digital input (N1500LC)
– 24 Vdc supply to power field transmitters, or 10 V supply to power a load cell (N1500LC)
– 4-20 mA output for process variable retransmission (optional)
– RS485 MODBUS RTU digital communication (optional)
– Universal 100-240 Vac/dc, 50/60 Hz switching power supply
– Circuit easily removable from the front, even while powered, without disconnecting the wiring
– Isolated output: 24 Vdc ±10 %, 35 mA or 10 Vdc ±0.5 %, 35 mA (N1500LC)
– Operation: 0 to 55 °C, 20 to 95 % RH, non-condensing
– Dimensions: 48 x 96 x 92 mm, panel cutout 45 x 93 mm
– Approximate weight: basic model (2 relays): 240 g. With options: 265 g.
– Front panel: IP65; polycarbonate (PC) UL94 V-2
– Housing: IP20; ABS + PC UL94 V-0

SKU CL33273 Category

Description

The N1500-LC indicator is the ideal instrument for monitoring analog variables in industrial processes with load cells.
Quick and easy to configure from the front keypad, the N1500-LC is compatible with the most common load cell signals, such as 0 to 20 mV, -20 to 20 mV, 0 to 50 mV, 0 to 20 mA and 4 to 20 mA.
The indicator has a keypad-programmable scale, configurable decimal point, a 10 V supply to power the load cell, an easy-to-read display, universal switching power supply and up to 4 alarm relays, 4 to 20 mA retransmission of the measured variable and RS485 digital communication with Modbus protocol.

Additional information

Type

Load cell indicator