Description
– Sensor measuring range:
Temperature: -40.0 °C to 100.0 °C (DM models) -40.0 °C to 60.0 °C (WM models)
Relative humidity: 0.0 to 100.0% RH (non-condensing)
Dew point: -90.0 °C to 100.0 °C
– Measurement resolution:
Temperature: 0.1 °C, 14 bits (65535 levels)
Relative humidity: 0.1%, 12 bits (4095 levels)
– Response time:
Temperature: up to 5 seconds at 25 °C with slow-moving air (1 m/s)
Humidity: up to 4 seconds at 25 °C with slow-moving air (1 m/s)
– Accuracy:
Temperature: ± 0.4 °C (0 °C to 60 °C)
Relative humidity: ± 1.8 % RH at 23 °C (0 % to 90 % RH)
– Sampling interval: 3 seconds
– Analog outputs: two 0-10 V or 4-20 mA outputs, configurable by software or keypad
– Power supply:
Via terminals: 12 Vdc to 30 Vdc; maximum consumption 70 mA +/- 10% @ 24 Vdc
Via USB: 4.75 Vdc to 5.25 Vdc
– Display: large backlit LCD showing three 4½-digit variables
– Keys: three touch-sensitive keys for navigation and parameter setting
– Alarms: two digital outputs and an internal buzzer
– Operating temperature: -40 to 60 °C
– Connections: internal terminals, through cable glands
– Dimensions: 100.3 x 80.0 x 45.1 mm
– Housing: ABS + PC
– Protection rating:
Housing: IP65
Sensor capsule: IP30
– Communication interfaces: Micro-B USB 2.0 and RS485 (both Modbus RTU)
– Programming: NXperience software for Windows